A. Feature High-tech design - Human rib style spring system. Blue-tooth communication - Evaluation is easier by applying wireless communication between the simulator and laptop computer - Simultaneous evaluation is possible by connecting multiple simulators to 1 laptop computer Over compression depth (7cm) - Over compression can be detected by measuring extra 1cm from AHA guideline. Semi-permanent AED electrode pads - Magnetic type AED electrodes can be used semi-permanently. Optimized GUI Software - Setting the CPR guideline for evaluation. - Revision of CPR guideline, points and checklist setting. - When training is done, training details and data will be saved and printed. Laptop(Option) Optimized GUI & Program - Build up evaluation Guideline - Modified guideline standard and setup the evaluation point & Checklist - Multi-Screen for the multiple monitoring of Simulator - All detail data and information is saved and print out anytime. Verification in real-time - Chest compressing, compression depth, position, rate, numbers and hands-off-time will be displayed in real-time. - Airway, the angle of patient’s head back will be displayed. (Hyperextension) - Artificial respiration, respiration volume, time, rate and numbers will be displayed in real-time. Automatic Carotid Pulse - Carotid Pulse Available (On/Off) 110/220V 50/60Hz Power Adaptor or battery B. Specification - Practice chest compression and artificial ventilation with CPR training simulator - Practice the pre-CPR procedures such as consciousness checking pulse checking and airway opening - Defibrillator / AED System for education Display windows - Trainee information : Saving and Printing the trainee information - Training procedure setup : setting the guideline, scenario, evaluation point, training time and checklist. - Training screen : · Trainee info. / Training time / Status of manikin / Chest compression and artificial ventilation data will be displayed. · Check consciousness : After the trainee check the patient’s consciousness, It will be marked at graph & history. · Check pulse : After the trainee check the patient’s carotid pulse, it will be marked at graph & history. · Chest compression : During the chest compression, compression depth, position, rate, number and hands-off-time will be marked at graph & history. · Airway opening : When opening the airway, it will be marked at graph & history. (Hyper-extention) · Artificial respiration : During artificial respiration, respiration volume, time, rate and numbers will be marked at graph & history. · Defibrillation : When applying the defibrillation, shock time and number will be marked at graph & history / ECG, pulse, breathing per minute, pupil will be marked at current state. - Accuracy analysis : Chest compression, artificial respiration will be displayed as a chart in real-time. - Practice record : All practice records from beginning to the end will be marked at graph & history. - Checklist : The supervisor’s checking results will be displayed. - History : When auto item & checklist is activated, the data will be displayed at practice record. - Metronome : Metronome setup. (OFF, 100bpm, 110bpm, 120bpm) - Scenario : According to setting ECG, ECG signal, pulse, breathing per minute, pupil will be displayed in real-time. - Evaluation result : · Trainee info, Result data display. · Total chest compression number, average depth, rate, hands-off-time, number of normal/ incomplete/ excessive depth, number of compression position (up, down, left, right side) and number of pressure relaxation and incomplete. · Total number of ventilation, average rate & volume, normal/ incomplete/ excessive volume of ventilation, number of stomach inflation, accurate ventilation and accuracy of artificial ventilation. · Total score and accuracy of assessment items will be displayed. · Item of runtime and total score will be displayed. · It is possible to save and print the results. - Previous result · Previous evaluation result of trainee can be uploaded. · Result summary / Training screen/ Accuracy analysis/ History’s selective display. · User can print out the data and transfer to excel. C. Components |