본문 바로가기 주메뉴 바로가기
BUSINESS AREA


BLS Training

  • cpr 평가.png

A. Feature

High-tech design

- Human rib style spring system.


Blue-tooth communication

- Evaluation is easier by applying wireless communication between the simulator and laptop computer

- Simultaneous evaluation is possible by connecting multiple simulators to 1 laptop computer


Over compression depth (7cm)

- Over compression can be detected by measuring extra 1cm from AHA guideline.


Semi-permanent AED electrode pads

- Magnetic type AED electrodes can be used semi-permanently.


Optimized GUI Software

- Setting the CPR guideline for evaluation.

- Revision of CPR guideline, points and checklist setting.

- When training is done, training details and data will be saved and printed.


Laptop(Option) Optimized GUI & Program

- Build up evaluation Guideline

- Modified guideline standard and setup the evaluation point & Checklist

- Multi-Screen for the multiple monitoring of Simulator

- All detail data and information is saved and print out anytime.


Verification in real-time

- Chest compressing, compression depth, position, rate, numbers and hands-off-time will be displayed in real-time.

- Airway, the angle of patient’s head back will be displayed. (Hyperextension)

- Artificial respiration, respiration volume, time, rate and numbers will be displayed in real-time.


Automatic Carotid Pulse

- Carotid Pulse Available (On/Off)


110/220V 50/60Hz Power Adaptor or battery





B. Specification

- Practice chest compression and artificial ventilation with CPR training simulator

- Practice the pre-CPR procedures such as consciousness checking pulse checking and airway opening

- Defibrillator / AED System for education


Display windows

- Trainee information : Saving and Printing the trainee information

- Training procedure setup : setting the guideline, scenario, evaluation point, training time and checklist.

- Training screen :

· Trainee info. / Training time / Status of manikin / Chest compression and artificial ventilation data will be displayed.

· Check consciousness : After the trainee check the patient’s consciousness, It will be marked at graph & history.

· Check pulse : After the trainee check the patient’s carotid pulse, it will be marked at graph & history.

· Chest compression : During the chest compression, compression depth, position, rate, number and hands-off-time will be marked at graph & history.

· Airway opening : When opening the airway, it will be marked at graph & history. (Hyper-extention)

· Artificial respiration : During artificial respiration, respiration volume, time, rate and numbers will be marked at graph & history.

· Defibrillation : When applying the defibrillation, shock time and number will be marked at graph & history / ECG, pulse, breathing per minute, pupil will be

  marked at current state.


- Accuracy analysis : Chest compression, artificial respiration will be displayed as a chart in real-time.

- Practice record : All practice records from beginning to the end will be marked at graph & history.

- Checklist : The supervisor’s checking results will be displayed.

- History : When auto item & checklist is activated, the data will be displayed at practice record.

- Metronome : Metronome setup. (OFF, 100bpm, 110bpm, 120bpm)

- Scenario : According to setting ECG, ECG signal, pulse, breathing per minute, pupil will be displayed in real-time.


- Evaluation result :

· Trainee info, Result data display.

· Total chest compression number, average depth, rate, hands-off-time, number of normal/ incomplete/ excessive depth, number of compression position

  (up, down, left, right side) and number of pressure relaxation and incomplete.

· Total number of ventilation, average rate & volume, normal/ incomplete/ excessive volume of ventilation, number of stomach inflation, accurate ventilation and

  accuracy of artificial ventilation.

· Total score and accuracy of assessment items will be displayed.

· Item of runtime and total score will be displayed.

· It is possible to save and print the results.


- Previous result

· Previous evaluation result of trainee can be uploaded.

· Result summary / Training screen/ Accuracy analysis/ History’s selective display.

· User can print out the data and transfer to excel.



C. Components






LIST